Medipur®

Super low-hardness urethane processed products mainly for medical simulated organs.
It is possible to produce surface conditions with greatly improved stickiness.

  • Heat resistance (70°C) and cold resistance (-30°C).
  • Can be used for soft, three-dimensional molding, not only for medical applications.
  • Non-yellowing type.
  • Hardness can be adjusted in the range of JIS E 0° to 50°.
  • Coloring can be done freely.
  • We can handle everything from prototype development to mass production using special equipment designed in-house.
Liver model

Liver model (reproduces the Young's modulus of the liver)

Physical property

Product Hardness Tensile strength
[MPa]
Elongation
[%]
100%
Modulus
[MPa]
200%
Modulus
[MPa]
Water absorption rate(23°C)
[%]
Water absorption rate(40°C)
[%]
Tear strength
[N/mm]
Specific gravity Compression set
[%]
[Type A] [Type E]
MPG-E5 0 5 0.6 450 0 0.1 5.1 3.2 2.2 1.049 3.3
MPG-E10 0 8 0.8 400 0 0.2 4.8 3.2 2.9 1.047 3.2
MPG-E15 3 14 0.8 340 0.1 0.2 4.4 2.6 3.8 1.049 2.3
MPG-E20 6 17 1.0 340 0.1 0.2 3.8 2.6 4.5 1.046 1.2
MPG-E30 15 28 1.2 260 0.2 0.6 2.7 2.2 5.7 1.043 1.4
Product MPG-E5 MPG-E10 MPG-E15 MPG-E20 MPG-E30
Hardness [Type A] 0 0 3 6 15
[Type B] 5 8 14 17 28
Tensile strength [MPa] 0.6 0.8 0.8 1.0 1.2
Elongation [%] 450 400 340 340 260
100% Modulus [Mpa] 0 0 0.1 0.1 0.2
200% Modulus [Mpa] 0.1 0.2 0.2 0.2 0.6
Water absorption rate(23°C) [%] 5.1 4.8 4.4 3.8 2.7
Water absorption rate(40°C) [%] 3.2 3.2 2.6 2.6 2.2
Tear strength [N/mm] 2.2 2.9 3.8 4.5 5.7
Specific gravity 1.049 1.047 1.049 1.046 1.043
Compression set [%] 3.3 3.2 2.3 1.2 1.4
*The measurement data shown on this website are examples of actual values measured using our test methods, not standard values.

[Measurement method]

Hardness: JIS K 6253, Tensile strength and modulus: JIS K 6251, Specific gravity (Submerged displacement method): JIS K 7112, Compression set (23°C, 22hr): JIS K 6262, Water absorption: JIS K 7209

[Test piece]

2 mm thick sheet

Applications

Cancer diagnosis model

Cancer diagnosis model for palpation awareness

The entire tongue is soft with JIS E5°. The shape and hardness of the tongue cancer area is also reproduced.
Femur model

Femur model with cancellous bone

Can be used for bolting and router cutting.
Uterine model

Uterine model

Liver model

Liver model

Breast cancer palpation model

Breast cancer palpation model

The position of the lump during palpation can be changed.
Stool extraction practice pit

Stool extraction practice pit

A simulated intestinal tract is inserted to reproduce a realistic texture.
Injection training model

Injection training model

The simulated blood vessel can be replaced for blood pouring practice.
Sacral model

Sacral model

PAGE TOP